Sensors

Differential pressure, dual

Two zone pairs in one sensor

Measures the pressure difference between two pairs of zones at once. Used for pressure cascades, where the air must move in one specific direction through several rooms.

DICKSON Differential pressure, dual

What is Differential pressure, dual, and how does it work?

Air moves from high to low pressure. If a cleanroom is kept at positive pressure relative to the corridor outside, air flows out through gaps and doors instead of in, and particles do not follow. If the pressure difference drops, the flow reverses and the protection disappears without anyone being able to see it.

The dual sensor has two channels and therefore measures two zone pairs at the same time. A cascade with four zones can then be followed with two sensors instead of four, and all measurements appear in the same graph.

Specifications

Measures

Differential pressure, 2 channels

Zone pairs

Two at once

Connects to

Cobalt X

Measuring range

See data sheet

Calibration

Traceable certificate

Replacement

Exchange without downtime

The measuring range is confirmed in the quote based on your qualification. Full specifications and the data sheet are included.

The product in use

The sensor is mounted outside the zone, and the tubes are run to the rooms to be compared. The data logger sits alongside and transmits wirelessly.

Each limit has its own delay, so a normal passage through the airlock does not trigger an alarm, while a sustained loss of pressure does.

DICKSON Differential pressure, dual, mounted between two airlock doors

How to get it

We do not sell individual parts over the counter. We put the setup together based on what we see on your site and take care of the rest.

01

Request a quote

Tell us what you want to monitor. We will come back with questions or a proposal.

02

Walkthrough

We visit, look at your equipment and rooms and advise on quantity and placement.

03

Installation

We install, set up limits and on-call rotas and train your staff in the system.

04

Operation and calibration

We look after it afterwards. Calibration on time and sensor exchange without downtime.

05

Validation

We validate the system, on our own or together with your QA, and deliver the documentation.

Frequently asked questions

How large should the pressure difference be?

That is set in your own qualification and depends on the zone class. We configure your figures, we do not decide them.

How do we avoid an alarm at every passage?

With a delay on each level. The pressure difference must stay outside the limit for the number of seconds or minutes you decide.

When should we choose the dual instead of the single?

When you have a cascade through several rooms. If you only have two zones to compare, the single is enough.

Get in touch with the right specialist quickly.

We help with everything from new monitoring solutions to calibration, validation and technical support.

General enquiries

New projects

IT and technical

Administration

Visit us

Måløv Byvej 229
2760 Måløv

Call us

Mon-Fri, 08-16

Tell us what you need.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Want to see how it would look at your site?

Book a walkthrough. We visit, look at your equipment and rooms and advise on where the sensors should go. You then get a tailored proposal. No obligation.

Book a walkthrough