Pt100 Smart-Sensor, -200 to +50
For ULT, cryo and liquid nitrogen
Platinum sensor for the data loggers, specified all the way down to -200 degrees. Used where ordinary digital sensors are no longer reliable.

What is the Pt100 Smart-Sensor, -200 to +50, and how does it work?
Pt100 is a platinum sensor. The electrical resistance of platinum changes predictably with temperature, and at 0 degrees the resistance is exactly 100 ohms. The relationship is known and stable all the way down to -200, and that is what makes it useful in the cold.
Ordinary digital temperature sensors are typically specified to around -40 degrees and drift below that, meaning they gradually read wrong without it showing in the number. In a -80 freezer this can mean the system reports that all is well while the actual temperature is -72.
The calibration coefficients are stored in the sensor itself. The data logger reads them directly, so a sensor can be swapped without configuring anything.
Specifications
Sensor type
Pt100 platinum
Measuring range
-200 to +50 degrees
Connects to
Cobalt X and Cobalt XS
Calibration
Data stored in the sensor
Traceability
Certificate in OCEAView
Replacement
Swap without downtime
Full specifications and the data sheet are sent with the quote.
The product in use
The sensor is fed into the freezer or tank through the access port, and the data logger stays outside on the wall.
For recalibration we send a new sensor with a certificate. You click it in, and measurement continues with no gap in the curve.

How to get it
We do not sell individual parts over the counter. We put the setup together based on what we see at your site and take care of the rest.
Request a quote
Tell us what you would like to monitor. We will get back to you with questions or a proposal.
Walkthrough
We visit, look at your equipment and premises and advise on number and placement.
Installation
We install, set up limits and on-call rotas and train your staff on the system.
Operation and calibration
We look after it afterwards. Calibration on time and sensor exchange without downtime.
Validation
We validate the system, on our own or together with your QA, and deliver the documentation.
Frequently asked questions
Why not an ordinary sensor for -80?
Because it is not specified for that range and drifts over time. Pt100 has a known uncertainty across the whole range.
How does the sensor get into the freezer?
Through the freezer's access port if it has one, otherwise through the door gasket without breaking the seal.
Do we need to configure anything when replacing it?
No. The calibration data is stored in the sensor, and the logger reads it automatically.
Related products
The equipment can be combined freely. We put the setup together based on what needs to be measured at your site.
Kom hurtigt i kontakt med den rette specialist.
Vi hjælper med alt fra nye monitoreringsløsninger til kalibrering, validering og teknisk support.
Generelle henvendelser
Nye projekter
IT & teknik
Administration
Besøg os
Måløv Byvej 229
2760 Måløv
Ring til os
+45 72 22 02 05
Man-fre, 08-16
Fortæl os, hvad du har brug for.
Vil du se, hvordan det ser ud hos jer?
Book en gennemgang. Vi kommer forbi, ser på udstyr og lokaler og rådgiver om, hvor følerne skal sidde. Derefter får du et skræddersyet forslag. Uden forpligtelser.
Book en gennemgang