Sensors

Pt100 Smart-Sensor, -200 to +50

For ULT, cryo and liquid nitrogen

Platinum sensor for the data loggers, specified all the way down to -200 degrees. Used where ordinary digital sensors are no longer reliable.

DICKSON Pt100 Smart-Sensor, -200 to +50

What is the Pt100 Smart-Sensor, -200 to +50, and how does it work?

Pt100 is a platinum sensor. The electrical resistance of platinum changes predictably with temperature, and at 0 degrees the resistance is exactly 100 ohms. The relationship is known and stable all the way down to -200, and that is what makes it useful in the cold.

Ordinary digital temperature sensors are typically specified to around -40 degrees and drift below that, meaning they gradually read wrong without it showing in the number. In a -80 freezer this can mean the system reports that all is well while the actual temperature is -72.

The calibration coefficients are stored in the sensor itself. The data logger reads them directly, so a sensor can be swapped without configuring anything.

Specifications

Sensor type

Pt100 platinum

Measuring range

-200 to +50 degrees

Connects to

Cobalt X and Cobalt XS

Calibration

Data stored in the sensor

Traceability

Certificate in OCEAView

Replacement

Swap without downtime

Full specifications and the data sheet are sent with the quote.

The product in use

The sensor is fed into the freezer or tank through the access port, and the data logger stays outside on the wall.

For recalibration we send a new sensor with a certificate. You click it in, and measurement continues with no gap in the curve.

DICKSON Pt100 Smart-Sensor, -200 to +50 in use

How to get it

We do not sell individual parts over the counter. We put the setup together based on what we see at your site and take care of the rest.

01

Request a quote

Tell us what you would like to monitor. We will get back to you with questions or a proposal.

02

Walkthrough

We visit, look at your equipment and premises and advise on number and placement.

03

Installation

We install, set up limits and on-call rotas and train your staff on the system.

04

Operation and calibration

We look after it afterwards. Calibration on time and sensor exchange without downtime.

05

Validation

We validate the system, on our own or together with your QA, and deliver the documentation.

Frequently asked questions

Why not an ordinary sensor for -80?

Because it is not specified for that range and drifts over time. Pt100 has a known uncertainty across the whole range.

How does the sensor get into the freezer?

Through the freezer's access port if it has one, otherwise through the door gasket without breaking the seal.

Do we need to configure anything when replacing it?

No. The calibration data is stored in the sensor, and the logger reads it automatically.

Kom hurtigt i kontakt med den rette specialist.

Vi hjælper med alt fra nye monitoreringsløsninger til kalibrering, validering og teknisk support.

Generelle henvendelser

Nye projekter

IT & teknik

Administration

Besøg os

Måløv Byvej 229
2760 Måløv

Ring til os

+45 72 22 02 05
Man-fre, 08-16

Fortæl os, hvad du har brug for.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Vil du se, hvordan det ser ud hos jer?

Book en gennemgang. Vi kommer forbi, ser på udstyr og lokaler og rådgiver om, hvor følerne skal sidde. Derefter får du et skræddersyet forslag. Uden forpligtelser.

Book en gennemgang