Pharma / Pharmaceutical production

Monitoring in GMP production

Temperature, humidity and differential pressure in production areas, cleanrooms, airlocks and intermediate storage. Measured continuously, alarmed in time and logged in an audit trail that cannot be altered.

Lab technician following the readings in OCEAView on screen

What needs to be monitored in GMP production?

The parameters that can affect product quality. In practice that means temperature and humidity in production areas and storage, differential pressure between cleanroom zones and airlocks, and temperature in process equipment and intermediate storage. The measurements must be continuous, alarmed and traceable to an accredited calibration.

The scope is set in your own risk assessment. We advise on sensor placement, but the decision on what to monitor is yours.

No cables through GMP walls

A cable penetration in a cleanroom wall is a change that has to be documented. With wireless, you avoid that discussion.

Bluetooth

Sensor to data logger

Used for the sensing. The sensor sits inside the equipment or behind the zone and sends to the logger without a cable.

LoRaWAN

Data logger to gateway

From here the signal is passed on. One gateway handles up to 50 data loggers and 100 to 200 sensors.

Wi-Fi

Smaller installations and fast logging

Cobalt XS Wi-Fi for smaller installations, or when a logging interval faster than 1 minute is needed.

Read about wireless monitoring

The deviation is caught before it becomes a deviation report

Via OCEAlert, the relevant staff are notified by call, SMS or email. If they do not answer, it moves down the on-call rota until someone acknowledges. Everything is logged.

OCEAView equipment list with department and room for each device

Equipment and location

Every device linked to a department and room, so the alarm points to a place and not a serial number.

OCEAView sensor overview with calibration certificate download

The certificate in the system

The calibration certificate is retrieved directly on the sensor. The system shows what needs calibrating, based on the intervals you have defined.

OCEAView alarm limits with delay per level

Limits with delay

Three levels up and three down. Each limit has its own delay, so an airlock in use does not trigger an alarm.

See OCEAView →

The documentation your QA asks for

We deliver the system and handle the validation, alone or in close cooperation with your QA.

Audit trail

Every reading, every alarm, every acknowledgement with timestamp and user. Cannot be altered.

Traceable certificates

The certificate is retrieved directly on the sensor in OCEAView.

Report in one click

Choose a period, export the report as PDF or CSV.

Requirements we support

GMP, GDP, EU GMP Annex 11, FDA 21 CFR Part 11 and ALCOA.

Read about audit trail and data integrity →

Case

Tappecenter Kolding

See how Tappecenter Kolding has set up monitoring and alarms so that a deviation reaches the right person, also outside working hours.

Read the full case

24/7

alarms with escalation

They already use us

Fertin PharmaCapital Region of DenmarkRegion of Southern DenmarkDTUSDU
See cases →

Frequently asked questions

Can the sensors sit in a cleanroom?

Yes. The sensors are small and can be cleaned. The data logger can sit outside the zone, so only the sensor is inside the room.

Do we need to break through the wall to run cables?

No. The sensor talks Bluetooth to the data logger, and the data logger talks LoRaWAN to the gateway. No penetration of zones.

How do we avoid false alarms when an airlock is in use?

Each alarm limit can have its own delay. The limit must be exceeded for the number of minutes you decide before the alarm goes off.

Can we monitor our particle counter in the same system?

Yes. Universal Smart-Sensor reads 4-20 mA, 0-5 V and 0-10 V, so third-party equipment sits in the same dashboard as everything else.

Who handles the validation?

We do, alone or together with your QA. You set the scope, and we carry out the validation and deliver the documentation.

Are FMS and EMS the same?

Yes. Facility Monitoring System and Environmental Monitoring System cover the same thing. The only difference is which term the industry uses.

Kom hurtigt i kontakt med den rette specialist.

Vi hjælper med alt fra nye monitoreringsløsninger til kalibrering, validering og teknisk support.

Generelle henvendelser

Nye projekter

IT & teknik

Administration

Besøg os

Måløv Byvej 229
2760 Måløv

Ring til os

+45 72 22 02 05
Man-fre, 08-16

Fortæl os, hvad du har brug for.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Vil du se, hvordan det ser ud hos jer?

Book en gennemgang. Vi kommer forbi, ser på udstyr og lokaler og rådgiver om, hvor følerne skal sidde. Derefter får du et skræddersyet forslag. Uden forpligtelser.

Book en gennemgang