Sensors

Smart DS

Temperature sensor with flat cable

The sensor used in refrigerators and freezers. A metal tip and a flat cable that passes through the door seal without deforming it.

DICKSON Smart DS

What is Smart DS, and how does it work?

Smart DS is a digital temperature sensor with the measuring element in a metal tip. What makes it well suited to cabinets is the cable. It is flat, so it can be routed through the door seal without holding the door ajar or damaging the seal over time.

The sensor connects to Cobalt X or Cobalt XS, which stores the measurements and sends them on. Calibration data is held in the sensor itself, so it can be exchanged without configuring the logger.

Specifications

Measures

Temperature

Cable

Flat, for door seals

Cable lengths

Several lengths

Connects to

Cobalt X and Cobalt XS

Calibration

Data held in the sensor

Replacement

Exchange without downtime

Full specifications and data sheet are sent with the quote.

The product in use

The sensor is placed inside the cabinet, typically in the middle and away from the cooling surface, so it measures what the medicine experiences and not the air at the evaporator.

The cable is routed out through the door seal, and the data logger is mounted on the wall next to the cabinet.

DICKSON Smart DS in use in a cold room

How to get it

We do not sell individual parts over the counter. We put the setup together based on what we see at your site and take care of the rest.

01

Request a quote

Tell us what you want to monitor. We will come back with questions or a proposal.

02

Walkthrough

We visit, look at your equipment and rooms and advise on quantity and placement.

03

Installation

We install, set up limits and on-call rotas and train your staff on the system.

04

Operation and calibration

We look after it afterwards. Calibration on time and sensor exchange without downtime.

05

Validation

We validate the system, on our own or together with your QA, and deliver the documentation.

Frequently asked questions

Does the cable damage the door seal?

No. The flat cable is designed for the purpose and does not deform the seal.

Where in the cabinet should the sensor go?

Typically in the middle and away from the cooling surface. We advise on placement during the walkthrough.

What if we cannot have a cable at all?

Then an Emerald sensor is used, mounted inside the cabinet with no cable.

Kom hurtigt i kontakt med den rette specialist.

Vi hjælper med alt fra nye monitoreringsløsninger til kalibrering, validering og teknisk support.

Generelle henvendelser

Nye projekter

IT & teknik

Administration

Besøg os

Måløv Byvej 229
2760 Måløv

Ring til os

+45 72 22 02 05
Man-fre, 08-16

Fortæl os, hvad du har brug for.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Vil du se, hvordan det ser ud hos jer?

Book en gennemgang. Vi kommer forbi, ser på udstyr og lokaler og rådgiver om, hvor følerne skal sidde. Derefter får du et skræddersyet forslag. Uden forpligtelser.

Book en gennemgang