Hospitals / Biobank and pathology

Monitoring of samples that cannot be replaced

ULT freezers, liquid nitrogen tanks and cold rooms with sample collections built up over years. Measured around the clock, alarmed while there is still time, and documented without gaps.

ULT freezer in a biobank

How do you monitor freezers and liquid nitrogen tanks in a biobank?

With fixed temperature sensors that measure continuously and send data to one combined system. From there, temperatures can be monitored, alarms handled and history documented.

The system also gives a technical alarm for lost communication and sensor faults, so a sensor does not quietly stop measuring.

The system also gives a technical alarm for lost communication and sensor faults, so a sensor does not quietly stop measuring.

A freezer can be replaced. The samples cannot

A biobank is often the result of many years of collection, and some of the samples exist in only one place. If a freezer breaks down, the freezer is not the loss.

The problem is rarely that nobody notices. The problem is that it is noticed too late. A ULT freezer warms up slowly, and over a weekend it gets a long way before anyone opens the door on Monday morning.

The alarm has to go off while the contents can still be moved to another freezer. That is the whole difference.

Sample boxes in a ULT freezer

What is a Pt100, and why does it matter at -80?

A Pt100 is a platinum sensor. The electrical resistance of platinum changes predictably with temperature, and at 0 degrees the resistance is exactly 100 ohms. That is what the name refers to. The relationship between resistance and temperature is known and stable all the way down to -200 degrees.

Ordinary digital temperature sensors are typically specified for a narrower temperature range, often down to around -40 °C. At temperatures around -80 °C they are therefore less suitable and may measure less precisely. Here Pt100 sensors are used, which are better suited to stable and precise measurements at very low temperatures.

When the temperature is around -80 °C, it places special demands on the sensor. That is why we use solutions developed for precise measurements at ultra-low temperatures.

The measuring range

-200 to +50 degrees for the cryo variant, -100 to +200 for the high-range one. ULT freezers and liquid nitrogen tanks both fall within this.

Traceability

The calibration coefficients are stored in the sensor itself. The certificate is retrieved directly from the sensor in OCEAView, so the accuracy can be documented.

The consequence

We typically recommend that you have 20-25 % extra sensors, so recalibration can run as an ongoing rotation. When a sensor needs calibrating, a spare sensor is put in its place, so monitoring continues without gaps in the readings.

Why a sensor drifts →

The alarm does not stop until someone answers

An email at two in the morning is rarely enough. Via OCEAlert the alarm can be sent as a phone call, SMS and email at the same time, and it moves down the on-call rota until someone acknowledges.

02.14-80.0 → -71.2 °C
LevelWarning
Delay10 min
Call 1No answer
SMSSent
EmailSent
Call 2Answered
Acknowledged byOn-call staff
Timestamp02.27
ActionMoved to backup
Duration23 min
Samples lost0
1

The deviation is registered

The temperature crosses the limit. The delay ensures that a brief door opening does not trigger an alarm.

2

OCEAlert

Call, SMS and email to the person on call. All at the same time, not instead of each other.

3

It escalates

If the first person does not answer, the system calls the next on the list and keeps going.

4

It is acknowledged

The acknowledgement is stored with name and timestamp in the audit trail along with all readings.

Read about alarms

OCEAView from DICKSON, set up and maintained by us

The hardware is DICKSON's. The software is DICKSON's. Everything between the equipment and your day-to-day work is ours. And once the system is in place, it is yours. You buy it, you own it, and no leasing agreement decides when you can switch, expand or stop. We take care of maintenance so it keeps running.

OCEAView

The whole setup on one screen. Watch mode gives a combined status overview of the equipment you have access to, with up to 100 units per page, and every graph can be zoomed down to the individual minute. Plan View also places the points on your own floor plan, so the person on call can see which room it concerns.

OCEAView Watch mode with a status overview of all measuring points
See OCEAView →

An audit trail that cannot be altered

Every reading, alarm and acknowledgement with timestamp and user. That is what an auditor asks for.

Report in one click

Choose a period and export the report as PDF or CSV. Ready before anyone asks.

Cloud or your own servers

On-premises runs at your site with LDAP, and you control updates yourselves, so the qualification holds.

DICKSON

The manufacturer

Builds data loggers, sensors and OCEAView. French and American production, its own accredited calibration laboratories and CE, FCC and IC approved equipment.

Djurhuus IT

Distributor since 2018

We advise on placement, design the setup, install, set up alarms and on-call rotas, train your staff on the system and manage calibration afterwards.

You

Owner of the system

The system is yours. You set the limits, response times and requirements according to your own SOPs. We supply the system and the documentation, handle the validation, on our own or in close cooperation with you, and maintain it afterwards.

Frequently asked questions

Why Pt100 and not an ordinary sensor?

We use a Pt100 Smart-Sensor. Ordinary temperature sensors are not specified for -80 degrees and drift over time in that range. Pt100, on the other hand, is. The Smart-Sensor part stores the calibration information in the sensor itself, so the accuracy can be documented and the certificate follows the sensor.

Does the sensor have to go inside the freezer?

Yes, the sensor itself. The data logger sits outside on the wall. The cable is fed through the freezer's access port or the door gasket without breaking the seal.

Can we also monitor liquid nitrogen tanks?

Yes. Pt100 rated to -200 degrees covers the range. This puts cryo freezers and liquid nitrogen tanks in the same dashboard as everything else.

Will we be notified if a sensor stops measuring?

Yes. The system gives a technical alarm for lost communication and sensor faults, so a silent sensor is not mistaken for a stable measuring point.

What happens during a power failure?

The data logger continues on battery, and the gateway can have backup. Dry contact on the backup power also raises an alarm when the system switches over.

How quickly do we need to react?

That depends on your own SOPs and on how quickly the specific equipment warms up. Delay and escalation are set up accordingly when we install.

Kom hurtigt i kontakt med den rette specialist.

Vi hjælper med alt fra nye monitoreringsløsninger til kalibrering, validering og teknisk support.

Generelle henvendelser

Nye projekter

IT & teknik

Administration

Besøg os

Måløv Byvej 229
2760 Måløv

Ring til os

+45 72 22 02 05
Man-fre, 08-16

Fortæl os, hvad du har brug for.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Vil du se, hvordan det ser ud hos jer?

Book en gennemgang. Vi kommer forbi, ser på udstyr og lokaler og rådgiver om, hvor følerne skal sidde. Derefter får du et skræddersyet forslag. Uden forpligtelser.

Book en gennemgang